Specification |
Model |
BDRP-240W-24 |
BDRP-240W-48 |
DC output |
24V 10A |
48V 5A |
Wave and noise |
50MVP-P |
50MVP-P |
Inlet stability |
±0.5% |
±0.5% |
Load stability |
±1% |
±0.5% |
Efficiency |
84% |
85% |
Adiustable range for DC voltage |
±10% |
±10% |
AC input voltage range |
85-264VAC 47-63HZ 124-370VDC |
AC Inrush current |
Cold-start current 27A/115VAC 45A/230V |
OverLoad protection |
105%--150% hiccup mode ,auto-recovery |
Over-voltage protection |
30--36V for 24Vmodel,54--60V for 48Vmodel |
Setup,rise,hold up time |
800ms, 40ms, 20ms/230VAC at full load |
Withstand voltage |
I/P-O/P:3KvAC I/P-FG:1.5Kv O/P-FG:0.5Kv1 minute |
Isolation resistance |
I/P-O/P I/P-FG O/P-FG:500VDC/100MΩ |
Working temperature |
~-10℃----+50℃ |
Safety standards |
Design refer to GB4943,UL60950,EN60950 |
EMC standards |
Design refer to GB9254,EN55022 classB |
Weight |
1.2kg |