Specification |
Model |
BDR-120W-12 |
BDR-120W-15 |
BDR-120W-24 |
BDR-120W-48 |
DC output |
12V 10A |
15V 8A |
24V 5A |
24V 2.5A |
Wave and noise |
75MVP-P |
75MVP-P |
75MVP-P |
75MVP-P |
Inlet stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±1% |
±0.5% |
±0.5% |
±0.5% |
Efficiency |
80% |
81% |
84% |
85% |
Adiustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
AC input voltage range |
AC110/ 220±20% Selected by switch |
AC Inrush current |
Cold-start current 20A/115VAC 40A/230V |
OverLoad protection |
105%--150% hiccup mode ,auto-recovery |
Over-voltage protection |
121%-142%rated output voltage |
Setup,rise,hold up time |
500ms, 70ms, 30ms at full load and 230VAC |
Withstand voltage |
I/P-O/P:3KvAC I/P-FG:1.5Kv O/P-FG:0.5Kv 1 minute |
Isolation resistance |
I/P-O/P I/P-FG O/P-FG:500VDC/100MΩ |
Working temperature |
~-10℃----+50℃ |
Safety standards |
Design refer to GB4943,UL60950,EN60950 |
EMC standards |
Design refer to GB9254,EN55022 classB |
Weight |
0.79kg |